NBPS True on-line Double Conversion Sine Wave UPS |
Property |
Reliable Power Quality • Input voltage 165 Vac - 264 Vac • Input frequency 50/60 Hz ± 10% suitable for industrial applications • Input power factor more than 0.99 at full load • Output voltage 220 Vac ± 1% • Crystal controlled output frequency 50/60 Hz ± 0.1% Smart Protection • 16/32 bit microcontroller UPS • 20 kHz PWM inverter • Built-in power factor correction • EMI/RFI and power line noise protection • Surge, spike, blackout, brownout, overload and short circuit protection • No break power backup scheme • Zero time transfer full static switch • Built-in sealed lead acid (maintenance free) battery • DC start (AC start without battery (C) is optional). • Manual maintenance bypass mode (M) (option) • Extended backup time with battery extension unit (option) • Hot standby configuration (H) (option) • Auto self-test every 2-week duration (T) (option) Power Display and Management • LED status and 16 Characters LCD display for monitoring and setting UPS parameter • 256 records event log (E) (option) Communication • Two RS-232 serial interface ports, one port for monitoring software (Easy-Mon X) and the other port for remote terminal (R) is optional. • Dry contact port (D) (option) • SNMP/HTTP monitor capability (S) (option) More Safety • Built in output isolation transformer • Load-Safe with new battery test scheme • Emergency Power Off (EPO) Energy Saving • High efficiency > 96% with Economy mode and Sleep mode • Automatic detective and shutdown when no load • Automatic battery charge power boosting (A) (option) |
Usability |
Smart • Better power control with Smart CPU Better monitor and configure with Smart display and management software Safe • Safer with isolation transformer • Safer load with new battery test scheme Safer protection for industrial applications Save • Saver energy with economy and sleep modes • Saver maintenance cost with more reliable products. |
Attribute |
|
MODEL |
NBP 3KS |
NBP 5KS |
NBP 6KS |
NBP 8KS |
NBP 10KS |
||
CAPACITY |
VA / W |
3000VA / 2400W |
5000VA / 4000W |
6000VA / 4800W |
8000VA / 6400W |
10,000VA/8000W |
|
INPUT |
Voltage (single phase) |
220 Vac -25%, +20%, (± 25% option) |
|||||
Frequency |
50 /60 Hz ± 10% at nominal voltage (± 12% option) |
||||||
Power factor |
more than 0.99 at full load |
||||||
OUTPUT |
Voltage (single phase) |
220 Vac ± 1% |
|||||
Frequency |
nominally locked to line frequency, free running 50 /60 Hz ± 0.1% (crystal controlled) |
||||||
Wave form |
pure sine wave (sinusoidal) |
||||||
Total harmonic distortion |
less than 3% at full linear load |
||||||
Transient condition |
less than 5% for 100% instantaneous load variation |
||||||
Overload capability |
150% for 30 sec., 125% for 15 min. |
||||||
Crest factor ratio |
3:1 |
||||||
Protection |
over heat, overload, over voltage, under voltage, short circuit proof and battery low voltage shutdown |
||||||
EFFICIENCY |
AC to AC (at full load, Pf.=1) |
> 88% |
|||||
Economy mode / Sleep mode |
> 96% |
||||||
BATTERY |
Type |
sealed lead acid (maintenance free) rechargeable |
|||||
Standard backup time (full load) |
more than 20 min. |
more than 12 min. |
more than 10 min. |
more than 20 min. |
more than 12 min. |
||
Special backup time (option) |
15 - 60 min. |
||||||
Recharge time |
less than 4 hours to 90% after full load discharge |
||||||
Management |
end of life indicator and alarm |
||||||
AUTOMATIC BYPASS SWITCH |
Capability |
150% for 10 minutes |
|||||
SURGE PROTECTION |
Standard energy |
UL recognized surge protection to std.1449 |
|||||
Ipeak |
170 joules (option 510 joules) (2 msec wave form) 8 kA (8/20 msec wave form) |
||||||
TRANSFER TIME |
Mains fail or recover |
Zero time (true online UPS) |
|||||
UPS to bypass and vice versa |
Zero time (make before break) |
||||||
Auto reverse |
After overload return to norma |
||||||
MANUAL CONTROLS |
Maintenance bypass switch |
option (M-code) |
|||||
INDICATOR |
Front panel LED's |
bypass input, line input, rectifier / charger, inverter, inverter supply, load level, overload, battery level, low battery, replace battery, automatic bypass, maintenance bypass, |
|||||
16 characters LCD Display |
input voltage, input frequency, output voltage, output current, output frequency, output power, % load, battery voltage, % battery, backup time, UPS status (load power factor and load power options (P-code)) |
||||||
AUDIBLE ALARM |
Two tones with reset for silence |
mains failure, low battery, replace battery, load on bypass, over temperature, fault |
|||||
FEATURES |
Automatic detective and |
yes (default setting is off) |
|||||
Manual self-test |
yes |
||||||
DC start |
yes |
||||||
AC start without battery |
option (C-code) |
||||||
INPUT |
Main input |
terminal with main input circuit breaker |
|||||
Bypass input |
terminal (bypass input circuit breaker option (I-code)) |
||||||
OUTPUT OUTLET |
terminal (output circuit breaker option (O-code)) |
||||||
COMMUNICATIONS INTERFACE |
RS232 port |
serial interface port can be connected to PC, workstations or servers for automatic unattended shutdown Easy-Mon X may be required. |
|||||
Remote terminal |
option (R-code) |
||||||
Remote status interface |
dry contact (option (D-code)) |
||||||
SNMP / HTTP capability |
internal or external (option (S-code)) |
||||||
ACOUSTIC NOISE |
At 1 metre |
< 50 dBA |
< 55 dBA |
||||
ENVIRONMENT |
Temperature |
0°C to 40°C |
|||||
Humidity |
0 - 95% (non-condensing) |
||||||
PHYSICAL DIMENSIONS |
UPS include standard battery |
27 x 79 x 78.5 |
60 x 90 x 110.5 |
||||
Battery Extension Unit (option) |
27 x 79 x 78.5 (option) |
60 x 90 x 110.5 (option) |
|||||
WEIGHT |
UPS include standard battery |
140 |
148 |
155 |
250 |
||
Battery Extension Unit (option) |
depend on battery capacity |
depend on battery capacity |
|||||
CONFORMANCE |
Design regulation |
IEC 62040-1, (2), EN 61000-4-2, (4), (6), IP21, TIS-1291 |