NBPS True on-line Double Conversion Sine Wave UPS
Property

Reliable Power Quality • Input voltage 165 Vac - 264 Vac • Input frequency 50/60 Hz ± 10% suitable for industrial applications • Input power factor more than 0.99 at full load • Output voltage 220 Vac ± 1% • Crystal controlled output frequency 50/60 Hz ± 0.1% Smart Protection • 16/32 bit microcontroller UPS • 20 kHz PWM inverter • Built-in power factor correction • EMI/RFI and power line noise protection • Surge, spike, blackout, brownout, overload and short circuit protection • No break power backup scheme • Zero time transfer full static switch • Built-in sealed lead acid (maintenance free) battery • DC start (AC start without battery (C) is optional). • Manual maintenance bypass mode (M) (option) • Extended backup time with battery extension unit (option) • Hot standby configuration (H) (option) • Auto self-test every 2-week duration (T) (option) Power Display and Management • LED status and 16 Characters LCD display for monitoring and setting UPS parameter • 256 records event log (E) (option) Communication • Two RS-232 serial interface ports, one port for monitoring software (Easy-Mon X) and the other port for remote terminal (R) is optional. • Dry contact port (D) (option) • SNMP/HTTP monitor capability (S) (option) More Safety • Built in output isolation transformer • Load-Safe with new battery test scheme • Emergency Power Off (EPO) Energy Saving • High efficiency > 96% with Economy mode and Sleep mode • Automatic detective and shutdown when no load • Automatic battery charge power boosting (A) (option)

Usability

Smart • Better power control with Smart CPU Better monitor and configure with Smart display and management software Safe • Safer with isolation transformer • Safer load with new battery test scheme Safer protection for industrial applications Save • Saver energy with economy and sleep modes • Saver maintenance cost with more reliable products.

Attribute

Specification

MODEL

NBP 3KS

NBP 5KS

NBP 6KS

NBP 8KS

NBP 10KS

CAPACITY

VA / W

3000VA / 2400W

5000VA / 4000W

6000VA / 4800W

8000VA / 6400W

10,000VA/8000W

INPUT

Voltage (single phase)

220 Vac -25%, +20%, (± 25% option)

Frequency

50 /60 Hz  ± 10% at nominal voltage (± 12% option)

Power factor

more than 0.99 at full load

OUTPUT

Voltage (single phase)

220 Vac ± 1%

Frequency

nominally locked to line frequency, free running 50 /60 Hz ± 0.1% (crystal controlled)

Wave form

pure sine wave (sinusoidal)

Total harmonic distortion

less than 3% at full linear load

Transient condition

less than 5% for 100% instantaneous load variation

Overload capability

150% for 30 sec., 125% for 15 min.

Crest factor ratio

3:1

Protection

over heat, overload, over voltage, under voltage, short circuit proof and battery low voltage shutdown

EFFICIENCY

AC to AC (at full load, Pf.=1)

> 88%

Economy mode / Sleep mode

> 96%

BATTERY

Type

sealed lead acid (maintenance free) rechargeable

Standard backup time

(full load)

more than 20 min.

more than 12 min.

more than 10 min.

more than 20 min.

more than 12 min.

Special backup time (option)

15 - 60 min.

Recharge time

less than 4 hours to 90% after full load discharge

Management

end of life indicator and alarm

AUTOMATIC BYPASS SWITCH

Capability

150% for 10 minutes
1500% for 1 cycle

SURGE PROTECTION

Standard energy

UL recognized surge protection to std.1449

Ipeak

170 joules (option 510 joules) (2 msec wave form) 8 kA (8/20 msec wave form)

TRANSFER TIME

Mains fail or recover

Zero time  (true online UPS)

UPS to bypass and vice versa

Zero time (make before break)

Auto reverse

After overload return to norma

MANUAL CONTROLS

Maintenance bypass switch

option (M-code)

INDICATOR

Front panel LED's

bypass input, line input, rectifier / charger, inverter, inverter supply, load level, overload, battery level, low battery, replace battery, automatic bypass, maintenance bypass,
UPS On, UPS shutdown, over temperature / fault, alarm

16 characters LCD Display

input voltage, input frequency, output voltage, output current, output frequency, output power, % load, battery voltage, % battery, backup time, UPS status (load power factor and load power options (P-code))

AUDIBLE ALARM

Two tones with reset for silence

mains failure, low battery, replace battery, load on bypass, over temperature, fault

FEATURES

Automatic detective and
shutdown when no load

yes (default setting is off)

Manual self-test

yes

DC start

yes

AC start without battery

option (C-code)

INPUT

Main input

terminal with main input circuit breaker

Bypass input

terminal (bypass input circuit breaker option (I-code))

OUTPUT OUTLET

 

terminal (output circuit breaker option (O-code))

COMMUNICATIONS INTERFACE

RS232 port

serial interface port can be connected to PC, workstations or servers for automatic unattended shutdown Easy-Mon X may be required.

Remote terminal

option (R-code)

Remote status interface

dry contact (option (D-code))

SNMP / HTTP capability

internal or external (option (S-code))

ACOUSTIC NOISE

At 1 metre

< 50 dBA

< 55 dBA

ENVIRONMENT

Temperature

0°C to 40°C

Humidity

0 - 95% (non-condensing)

PHYSICAL DIMENSIONS
(W x H x D) (cm)

UPS include standard battery

27 x 79 x 78.5

60 x 90 x 110.5

Battery Extension Unit (option)

27 x 79 x 78.5 (option)

60 x 90 x 110.5 (option)

WEIGHT
(Approximate in kg.)

UPS include standard battery

140

148

155

250

Battery Extension Unit (option)

depend on battery capacity

depend on battery capacity

CONFORMANCE

Design regulation

IEC 62040-1, (2), EN 61000-4-2, (4), (6), IP21, TIS-1291