0-2181-5144-6
0-2181-5148
Price
all.
Voltage & Current Recorder Model: MCR-4V
Property

Measure and record data for control devices and measurement instruments in factories., Record signals from actinometers, anemoscopes and CO2 meters., Record output signals from a variety of sensors and analyzers., Measure voltage in electrical circuits.

Usability

Attribute

Specification
Model MCR-4V
Measurement Channels Voltage 4ch
Input Method Scanning Method, Differential Input, Each Channel Isolated
Input Impedance Approx. 1.1 MΩ
Input Frequency DC-100 Hz
Measurement Range ±300 mV, ±1.5 V, ±6 V, ±24 V, Auto (*1) Absolute Maximum Input Voltage: ±50 V
Accuracy When the 50-60 Hz filter is ON, varies with the Measurement Range as
follows:
±300 mV : ±( 0.3 % + 0.06 mV )
±1.5 V : ±( 0.3 % + 0.3 mV )
±6 V : ±( 0.3 % + 0.6 mV )
±24 V : ±( 0.3 % + 2.4 mV )
Auto : According to the range in use
Measurement Resolution 50 - 60 Hz Filter ON : 0.01 mV
50 - 60 Hz Filter OFF : 0.1 mV
Preheat Function Allowable Voltage Range : 3 to 24 V ( external power supply )
Allowable Maximum Current : 1.0 A
Recording Method Instantaneous, Average, or Ave. Fine
Recording Interval 2, 5, 10, 20, 50, 100, 200, 500 ms. / 1, 2, 5, 10, 15, 20, 30 sec.
1, 2, 5, 10, 15, 20, 30, 60 min.
( The minimum interval will depend on the number of channels, measurement range, and 50-60 Hz filter setting. )
Logging Capacity (*2) When recording 1 channel : up to 480,000 readings/ch
When recording 2 channels : up to 240,000 readings/ch
When recording 3 channels : up to 160,000 readings/ch
When recording 4 channels : up to 120,000 readings/ch
Recording Mode Endless ( Overwrite the most recent data when capacity is full ) or One Time ( Stop recording when capacity is full )
Recording Start Method Immediate Start or Programmed Start ( by individual logger or by group )
Recording Stop Trigger ON or OFF
Group Recording Up to 4 units ( 16 channels ) can be recorded simultaneously. (Coupling of MCR-4V and MCR-4TC is possible. (*3)
LCD Display Items Measurements, Trend Graph, Battery Level, etc.
Communication Interfaces USB Communication
Communication Time Download Times for Full Data via USB
- While recording ( at recording interval of 2 ms. ) : Approx. 3 minutes 30 seconds
- With recording stopped: Approx. 1 minute 30 seconds
- From a slave unit: Approx. 4 minutes 30 seconds
External Memory SD Memory Card, SDHC Memory Card (*4) ( For Manual or Automatic Data Export )
Power AA Alkaline Battery x 2 ( AA Ni-MH batteries may also be used ), USB Power ( 5 V 250 mA )
Battery Life (*5) Approx. 4.5 to 150 days ( with AA alkaline batteries )
Input Terminal / Preheat Terminal Screwless Terminals Single Wire : Ø0.32 to Ø0.65 mm ( AWG 28 - 22 )
Twisted Wire : 0.08 to 0.32 mm2 ( AWG 28 - 22 ), Ø0.12 mm or more in diameter Stripping Length : 9 to 10 mm
Isolation

CH1, CH2, CH3, CH4, USB, and Preheat are isolated.

( Battery terminals are not isolated from the CH1-CH4 input terminals. ) CH1- CH4 Maximum Applied Voltage : ± 50 V
Electrical Isolation Resistance : 50 MΩ or more ( DC ± 250 V )

Dimensions H 120 mm x W 75 mm x D 32 mm
Weight Approx. 190 g ( including batteries )
Operating Environment Temperature: 0 to 50 °C
Humidity: 90 %RH or less ( no condensation )
Accessories AA Alkaline Battery x 2, USB Communication Cable
Accessories AA Alkaline Battery x 2, USB Communication Cable ( US-15C ),
Software ( CD-ROM ), Card Slot Cover, User's Manual Set ( Warranty Included )
Compatible Devices MCR-4V, MCR-4TC
Compatible OS (**1) Microsoft Windows 8 32 / 64 bit (**2)
Microsoft Windows 7 32 / 64 bit
Microsoft Windows Vista 32 bit ( SP1 or later )
Microsoft Windows XP 32 bit ( SP3 or later )
Display Languages (**3) English
Other The .NET Framework 4 Client Profile is required. (**4)

*1: When "Auto" is selected, measurement range will be automatically changed according to the voltage being measured.
*2: If the logging capacity is not filled at the end of one recording session, the logger can record up to 30 times.
*3: Group Recording may not be started depending on the recording or measurement intervalspecifications of the connected Master unit.
*4: Please check the T&D Website for information on memory cards whose operation has been confirmed.
*5: Battery life varies depending upon multiple factors including measurement interval and 50-60 Hz filter setting. All estimates are based on operations carried out

with a new battery and are in no way aguarantee of actual battery life.

**1: For installation, it is necessary to have Administrator (Computer Administrator) rights.
**2: If you are using Windows 8, please note that our software is designed to be used in "Desktop" modeonly.
**3: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
**4: During the installation process of the software, if not present, .NET Framework 4 Client Profile will be installed automatically.