NB31 TRUE ON-LINE DOUBLE CONVERSION SINE WAVE UPS (LED and LCD DISPLAY) |
Property |
• Latest IGBT technology for highest reliability • 100% backup guarantee with no break power • Zero time static bypass • Computer interface • Input voltage 380/415 Vac ± 20% three phase • Output voltage 220/240 Vac ± 1% single phase • Built-in output isolation transformer • Crystal controlled frequency 50/60 Hz ± 0.1% • LED and LCD display • Surge, spike, blackout, brownout, overload and short circuit protection • EMI/RFI and power line noise protection • Double overload protection • Battery equalize function (option) • Output frequency synchronization range selectable • Manual controlled transfer switch 3 modes selectable • SNMP/HTTP monitor capability (option) |
Usability |
LEONICS UPS with range from 350 VA to 250 kVA is also widely used to protect electronic equipment such as computer networks, PABX, telecommunications, medical and scientific equipment, etc. from blackout, brownout, surge, spike, noise and frequency drift. |
Attribute |
|
MODEL |
NB 0831 |
NB 1031 |
NB 1231 |
NB 1531 |
NB 2031 |
NB 2531 |
NB 3031 |
NB 4031 |
|
CAPACITY |
Pf. = 0.8 |
8 kVA |
10 kVA |
12 kVA |
15 kVA |
20 kVA |
25 kVA |
30 kVA |
40 kVA |
INPUT |
Voltage Voltage range Frequency |
380 Vac 3 phase 4 wires |
|||||||
OUTPUT |
Voltage Frequency Wave form |
220 Vac ± 1% |
|||||||
EFFICIENCY |
AC to AC (at full load) |
88% |
90% |
90% |
91% |
91% |
92% |
92% |
92% |
BATTERY |
Type |
sealed lead acid (maintenance free) rechargeable |
|||||||
Voltage |
360 Vdc |
||||||||
Standard backup time |
> 12 min. |
> 10 min. |
> 12 min. |
> 10 min. |
> 10 min. |
> 10 min. |
> 10 min. |
> 7 min. |
|
Special backup time |
15 - 60 min. |
||||||||
Recharge time |
6-8 hours to 90% after full load discharge |
||||||||
AUTOMATIC BYPASS |
Capability |
300% for 5 minutes |
|||||||
SURGE PROTECTION |
Standard |
UL recognized surge protection to std.1449 |
|||||||
Energy absorption |
400 joules (10/100 microsec. wave form) |
||||||||
Surge current capability |
40 kA (8/20 microsec. wave form) |
||||||||
TRANSFER TIME |
Mains fail or recover |
zero time (true online UPS) |
|||||||
UPS to bypass and vice versa |
zero time (make before break) after overload return to normal |
||||||||
MANUAL CONTROLS |
Maintenance bypass switch |
yes |
|||||||
Automatic bypass switch |
mode selectable : automatic bypass, inverter only, bypass only (option) |
||||||||
INDICATOR |
Front panel LED's |
main 1 input / rectifier ,main 2 input, inverter, inverter supply, automatic bypass, maintenance bypass, |
|||||||
LCD Display |
main 1 input voltage (V12 input voltage, V23 input voltage, V31 input voltage), main 2 input voltage, output voltage, % load, % battery |
||||||||
AUDIBLE ALARM |
Two tones with reset for silence |
mains failure, fault, over temperature, battery approaches final discharge |
|||||||
AUTOMATIC DETECTIVE AND |
yes |
||||||||
COMMUNICATION |
Dry contract (DB 9) |
yes |
|||||||
SNMP / HTTP capability |
option (internal or external) |
||||||||
ACOUSTIC NOISE |
At 1 metre |
<55 dBA |
|||||||
FEATURE |
Voltage free contact |
main, inverter, static switch, battery, alarm and UPS fault status (standard) |
|||||||
Remote panel |
option |
||||||||
Hot stand-by config |
standard |
||||||||
ENVIRONMENT |
Temperature |
0°C to 40°C |
|||||||
Humidity |
0 - 95% (non-condensing) |
||||||||
WEIGHT |
UPS |
191.5 |
237.5 |
337 |
458 |
510 |
|||
Battery cabinet |
173 |
350 |
|||||||
PHYSICAL DIMENSIONS |
UPS (W x H x D) |
43 x 94.2 x 83 |
43x110x83 |
65 x 94.2 x 88 |
|||||
Battery (W x H x D) |
43 x 31.2x 86.5 |
43 x 78.4 x 86.5 |
|||||||
UPS include battery (W x H x D) |
43 x 125.4 x 86.5 seperate (UPS and battery cabinet) |