Voltage Data Logger, Model : RVR-52A |
Property |
- Voltage/Pulse Recorder with External Load Input. |
Usability |
- Wireless Communication, range about 100 meters.(if direct and unobstructed) |
Attribute |
|
Measurement Channel | 1 Ch (Voltage) | 1 Ch (Pulse) | 1 Ch (Event) |
Input Voltage Range | 0 to 6.5V | 0 to 30V | 0 to 30V |
Measurement Display Resolution | 1mV | - | 1sec. |
Measurement Accuracy |
±0.5%+5dgt (at 0 to 40) |
- | - |
Detection Voltage | - | Lo: below 0.6V / Hi: above 2V | |
Response Time | - |
30Hz / Approx.15 sec. or more (over 2.5V) |
1 sec. |
Response Polarity | - | Pu: select Lo-Hi or Hi-Lo | Ev: Both Lo -Hi and Hi-Lo |
Highest No. of Counts | - | Pu: 32,000Counts | - |
Input Impedance | Approx. 1M | Pu, Ev: Pull-up Resistor Approx.100k | |
Logging Capacity | 16,000 readings | 16,000 readings | 8,000 readings |
Recording Intervals |
1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min.Total of 15 choices (excluding event data) |
||
Recording Mode |
Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full) |
||
LCD Display Items |
Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data. |
||
Power |
Lithium Battery (LS14250(SAFT) for L Series: Large Capacity Battery Adaptor Kit (RTR-05B1) External Power Adaptor Kit (RTR-05A1) (sold seprately) |
||
Battery Life(*4) | Approx. 6 months / L Series: Approx 2 years and 6 months | ||
Radio Standard Specifications |
ETSI EN 300-220 [ Frequency Range: 433.050 to 434.79MHz ], FCC Part15 Section249 / IC RSS-210 [ Frequency Range: 902 to 928MHz ] |
||
Transmission Range | Approx. 100m (May vary with conditions) | ||
Dimensions |
H62mm x W 47mm x D19mm(D46.5mm:L Series) (excluding protrusions / antenna length 20mm) |
||
Communication Interfaces | Wireless Communication / Optical Communication | ||
Communication Speed |
When downloading data (Wireless) about 2,000 readings per min. [Collection of a full unit of data= about 420 sec. (optical communication= about 160 sec.)] |
||
Water Resistance | IP64 (rated for use in daily life) | ||
Standard Sensor / Input Cable | RPR-7101 (Length: about 1.5m) x 1 | ||
Unit Temp. Resistance | -30 to 80°C (Unit temp resistance and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C ) | ||
Others |
The RVR-52A includes an internal pre-heat function which sends signals to turn ON / OFF external sensors, etc...in time with the starting of recording. Possible to measure current with the RVR-5203 4-20mA Probe. In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. For optical communication, TR-50C can also be used for all types of units. |