Price | ||
Voltage & Current Recorder Model: MCR-4V |
Property |
Measure and record data for control devices and measurement instruments in factories., Record signals from actinometers, anemoscopes and CO2 meters., Record output signals from a variety of sensors and analyzers., Measure voltage in electrical circuits. |
Usability |
|
Attribute |
|
Model | MCR-4V |
Measurement Channels | Voltage 4ch |
Input Method | Scanning Method, Differential Input, Each Channel Isolated |
Input Impedance | Approx. 1.1 MΩ |
Input Frequency | DC-100 Hz |
Measurement Range | ±300 mV, ±1.5 V, ±6 V, ±24 V, Auto (*1) Absolute Maximum Input Voltage: ±50 V |
Accuracy | When the 50-60 Hz filter is ON, varies with the Measurement Range as follows: ±300 mV : ±( 0.3 % + 0.06 mV ) ±1.5 V : ±( 0.3 % + 0.3 mV ) ±6 V : ±( 0.3 % + 0.6 mV ) ±24 V : ±( 0.3 % + 2.4 mV ) Auto : According to the range in use |
Measurement Resolution | 50 - 60 Hz Filter ON : 0.01 mV 50 - 60 Hz Filter OFF : 0.1 mV |
Preheat Function | Allowable Voltage Range : 3 to 24 V ( external power supply ) Allowable Maximum Current : 1.0 A |
Recording Method | Instantaneous, Average, or Ave. Fine |
Recording Interval | 2, 5, 10, 20, 50, 100, 200, 500 ms. / 1, 2, 5, 10, 15, 20, 30 sec. 1, 2, 5, 10, 15, 20, 30, 60 min. ( The minimum interval will depend on the number of channels, measurement range, and 50-60 Hz filter setting. ) |
Logging Capacity (*2) | When recording 1 channel : up to 480,000 readings/ch When recording 2 channels : up to 240,000 readings/ch When recording 3 channels : up to 160,000 readings/ch When recording 4 channels : up to 120,000 readings/ch |
Recording Mode | Endless ( Overwrite the most recent data when capacity is full ) or One Time ( Stop recording when capacity is full ) |
Recording Start Method | Immediate Start or Programmed Start ( by individual logger or by group ) |
Recording Stop Trigger | ON or OFF |
Group Recording | Up to 4 units ( 16 channels ) can be recorded simultaneously. (Coupling of MCR-4V and MCR-4TC is possible. (*3) |
LCD Display Items | Measurements, Trend Graph, Battery Level, etc. |
Communication Interfaces | USB Communication |
Communication Time | Download Times for Full Data via USB - While recording ( at recording interval of 2 ms. ) : Approx. 3 minutes 30 seconds - With recording stopped: Approx. 1 minute 30 seconds - From a slave unit: Approx. 4 minutes 30 seconds |
External Memory | SD Memory Card, SDHC Memory Card (*4) ( For Manual or Automatic Data Export ) |
Power | AA Alkaline Battery x 2 ( AA Ni-MH batteries may also be used ), USB Power ( 5 V 250 mA ) |
Battery Life (*5) | Approx. 4.5 to 150 days ( with AA alkaline batteries ) |
Input Terminal / Preheat Terminal | Screwless Terminals Single Wire : Ø0.32 to Ø0.65 mm ( AWG 28 - 22 ) Twisted Wire : 0.08 to 0.32 mm2 ( AWG 28 - 22 ), Ø0.12 mm or more in diameter Stripping Length : 9 to 10 mm |
Isolation |
CH1, CH2, CH3, CH4, USB, and Preheat are isolated. ( Battery terminals are not isolated from the CH1-CH4 input terminals. ) CH1- CH4 Maximum Applied Voltage : ± 50 V |
Dimensions | H 120 mm x W 75 mm x D 32 mm |
Weight | Approx. 190 g ( including batteries ) |
Operating Environment | Temperature: 0 to 50 °C Humidity: 90 %RH or less ( no condensation ) Accessories AA Alkaline Battery x 2, USB Communication Cable |
Accessories | AA Alkaline Battery x 2, USB Communication Cable ( US-15C ), Software ( CD-ROM ), Card Slot Cover, User's Manual Set ( Warranty Included ) |
Compatible Devices | MCR-4V, MCR-4TC |
Compatible OS (**1) | Microsoft Windows 8 32 / 64 bit (**2) Microsoft Windows 7 32 / 64 bit Microsoft Windows Vista 32 bit ( SP1 or later ) Microsoft Windows XP 32 bit ( SP3 or later ) |
Display Languages (**3) | English |
Other | The .NET Framework 4 Client Profile is required. (**4) |
*1: When "Auto" is selected, measurement range will be automatically changed according to the voltage being measured.
*2: If the logging capacity is not filled at the end of one recording session, the logger can record up to 30 times.
*3: Group Recording may not be started depending on the recording or measurement intervalspecifications of the connected Master unit.
*4: Please check the T&D Website for information on memory cards whose operation has been confirmed.
*5: Battery life varies depending upon multiple factors including measurement interval and 50-60 Hz filter setting. All estimates are based on operations carried out
with a new battery and are in no way aguarantee of actual battery life.
**1: For installation, it is necessary to have Administrator (Computer Administrator) rights.
**2: If you are using Windows 8, please note that our software is designed to be used in "Desktop" modeonly.
**3: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
**4: During the installation process of the software, if not present, .NET Framework 4 Client Profile will be installed automatically.